When choosing a 350 kVA Perkins diesel generator, two prominent engine models come to mind: the 1706A-E93TAG2 and the 2206A-E13TAG2. Both engines are designed to provide reliable power, but they feature differences in design, performance, and specifications that may influence your choice based on specific needs.
They both have the same capacity, powered by a 350 kVA Perkins Diesel Engine, but their variations lie in engine displacement, fuel efficiency, and operational capabilities. To make an informed decision, it is essential to analyze the Technical Data Sheets of both models, available on the Empower website, which highlight their unique attributes and applications.
Engine Overview
Perkins 1706A-E93TAG2
The 1706A-E93TAG2 is part of Perkins’ 1700 Series, engineered to offer superior performance and flexibility. Developed on a modern 9.3-liter core, this engine is designed for efficiency and adaptability, making it a suitable choice for various power generation needs.
Perkins 2206A-E13TAG2
Belonging to the 2200 Series, the 2206A-E13TAG2 is a 6-cylinder, turbocharged, air-to-air charge-cooled diesel engine. It provides an exceptional power-to-weight ratio, resulting in impressive fuel efficiency. This engine is developed from a proven heavy-duty industrial base, ensuring superior performance and reliability.
Technical Specifications
The following table summarizes the key technical specifications of both engines:
Specification | 1706A-E93TAG2 | 2206A-E13TAG2 |
---|---|---|
Number of Cylinders | 6 in-line | 6 in-line |
Displacement | 9.3 liters | 12.5 liters |
Bore and Stroke | 115 x 149 mm | 130 x 157 mm |
Aspiration | Turbocharged and air-to-air charge cooled | Turbocharged and air-to-air charge cooled |
Compression Ratio | 16.0:1 | 16.3:1 |
Rated Speed | 1500/1800 rpm | 1500/1800 rpm |
Prime Power Output (50 Hz) | 350 kVA | 350-400 kVA |
Standby Power Output (50 Hz) | 385 kVA | 400-450 kVA |
Performance Characteristics
Power Output
While both engines are rated for 350 kVA at prime power, the 2206A-E13TAG2 offers a broader range, supporting up to 400 kVA. For standby power, the 2206A-E13TAG2 provides up to 450 kVA, whereas the 1706A-E93TAG2 offers up to 385 kVA.
Fuel Efficiency
The 1706A-E93TAG2 boasts a 5% improvement in fluid consumption compared to previous models, highlighting its efficiency. Specific fuel consumption data for the 2206A-E13TAG2 is not provided in the available sources, but its design emphasizes exceptional fuel efficiency.
Design and Dimensions
Physical Dimensions
The 1706A-E93TAG2, with its 9.3-liter displacement, typically has a more compact design compared to the 12.5-liter 2206A-E13TAG2. This difference can influence installation space requirements and transportation considerations.
Weight
Generally, engines with larger displacements, like the 2206A-E13TAG2, tend to weigh more than those with smaller displacements. However, specific weight data is not available in the provided sources.
Applications and Suitability
1706A-E93TAG2
This engine is well-suited for applications requiring a compact and efficient power solution. Its improved fluid consumption and flexible packaging make it ideal for installations where space and operational efficiency are critical.
2206A-E13TAG2
With its higher power output capabilities and robust design, the 2206A-E13TAG2 is suitable for demanding applications that may require additional power during peak times or future expansion. Its exceptional power-to-weight ratio and fuel efficiency make it a reliable choice for continuous and standby power needs.
Availability in Pakistan
Empowering is committed to delivering Perkins diesel generators across Pakistan, including major cities like Lahore, Islamabad, Karachi, Faisalabad, and Peshawar. Both the 1706A-E93TAG2 and 2206A-E13TAG2 models are available, ensuring that clients have access to power solutions tailored to their specific requirements.
Conclusion
Choosing between the Perkins 1706A-E93TAG2 and the 2206A-E13TAG2 depends on specific power needs, space constraints, and efficiency considerations. The 1706A-E93TAG2 offers a compact and efficient solution, ideal for installations where space and fuel economy are priorities.
In contrast, the 2206A-E13TAG2 provides higher power capabilities and is suited for applications requiring robust performance and potential for future power needs. Empowering ensures the availability of both models across Pakistan, catering to diverse power generation requirements.
Frequently Asked Questions
What are the key differences between the Perkins 1706A-E93TAG2 and 2206A-E13TAG2?
The 1706A-E93TAG2 has a 9.3L engine, whereas the 2206A-E13TAG2 has a 12.5L engine, making it more powerful. The 2206A-E13TAG2 also provides higher standby power and torque, making it more suitable for industrial applications, while the 1706A-E93TAG2 is more compact and fuel-efficient.
Which generator is more fuel-efficient?
The 1706A-E93TAG2 is designed for better fuel efficiency, consuming less fuel per hour compared to the 2206A-E13TAG2. If fuel savings and cost-effectiveness are a priority, the 1706A-E93TAG2 is a better choice. However, the 2206A-E13TAG2 provides more power and is suited for high-load applications.
Can both generators be used for commercial and industrial purposes?
Yes, both generators are ideal for commercial and industrial use. The 1706A-E93TAG2 is better suited for offices, small businesses, and urban environments, whereas the 2206A-E13TAG2 is perfect for large industries, factories, and heavy-duty applications due to its higher torque and power capacity.
What are the maintenance requirements for these generators?
Both generators require regular maintenance, including oil changes, filter replacements, and coolant checks. The 2206A-E13TAG2, with its larger engine and higher power output, may require more frequent servicing compared to the 1706A-E93TAG2 to maintain optimal performance.
Where can I buy Perkins diesel generators in Pakistan?
Empowering supplies Perkins diesel generators in major cities like Lahore, Islamabad, Karachi, Faisalabad, and Peshawar. We offer nationwide delivery and expert consultation to help you choose the right generator for your power needs. Contact Us today.